Template will be inserted on upload Post BD spirometry file using form_set_device_answers() if there is no predetermined template in current program.
The elements that compose this system form are:
Element | DATA_CODE | Description |
---|---|---|
TEXT | FORM.DATA.HEIGHT_PBD | Height (m) |
TEXT | FORM.DATA.WEIGHT_PBD | Weight (Kg) |
NUMERICAL | FORM.DATA.SPIRO.PBD.PFVC | <b>FVC</b> (Forced Vital Capacity) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.PFEV1 | <b>FEV1</b> (Forced Expiratory Volume during the first second) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.PPEF | PEF (Peak Expiratory Flow) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.PFEF25 | FEF25 (Forced Expiratory Flow at 25% of the forced vital capacity) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.PFEF50 | FEF50 (Forced Expiratory Flow at 50% of the forced vital capacity) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.PFEF2575 | FEF25/75(litres)(Forced Expiratory Flow Between 25% and 75% of Forced Vital Capacity) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FVC | <b>FVC</b> (Forced Vital Capacity) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEV1 | <b>FEV1</b> (Forced Expiratory Volume during the first second) (L) |
HORIZONTAL_RADIO | FORM.DATA.SPIRO.PBD.QUALITY | QUALITY |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEV6 | FEV6 (Best forced volume in the 6th second) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.BE | BEV (Extrapolated volume) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.PEFT | PEFT (Peak Expiratory Flow Time) (s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.PEF | PEF (Peak Expiratory Flow) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEF25 | FEF25 (Forced Expiratory Flow at 25% of the forced vital capacity) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEF50 | FEF50 (Forced Expiratory Flow at 50% of the forced vital capacity) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEF75 | FEF75 (Forced Expiratory Flow at 75% of the forced vital capacity) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEF2575 | FEF25/75(litres)(Forced Expiratory Flow Between 25% and 75% of Forced Vital Capacity) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FET2575 | FET2575(%) |
NUMERICAL | FORM.DATA.SPIRO.PBD.EOTV | EOTV (End of test volume) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.TZERO | TZERO (Time-zero volume) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FIF50 | FIF50 (Forced Inspiratory Flow at 50% of the forced vital capacity) (L/s) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FIVC | FIVC (Forced Inspiratory Vital Capacity) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.ERFP | ERFP |
NUMERICAL | FORM.DATA.SPIRO.PBD.ERTP | ERTP |
NUMERICAL | FORM.DATA.SPIRO.PBD.EREX | EREX |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEV05 | FEV0.5 (Forced Expiratory Volume in 0.5 Seconds) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEV3 | FEV3 (Forced Expiratory Volume in 3 Seconds) (L) |
NUMERICAL | FORM.DATA.SPIRO.PBD.FET | FET (forced expiratory time) (s) |
NUMERICAL | FORM.DATA.RANKING_SPIRO_PBD | Ranking |
GRAPH | FORM.DATA.#GRAPH:ESPIRO:VT | Volume Graph |
GRAPH | FORM.DATA.#GRAPH:ESPIRO:FV | Flow/Volume Graph |
GRAPH | FORM.DATA.#GRAPH:ESPIRO:FT | Hidden Flow/Time Graph |
NUMERICAL | FORM.DATA.SPIRO.PBD.FEV1-FVC | Hidden FEV1/FVC |
NUMERICAL | FORM.DATA.SPIRO.PBD.PFEV1FVC | Hidden FEV1/FVC_REF |
, multiple selections available,